The spray cooling tank is newly optimized stainless steel pipes with 5800 mm length and 304 stainless steel thickened vacuum tank. The open sliding door structure is adopted for the specification above 250(including), and the pipe drying device is added for the smal-sized pipe,which can meet the needs of customers.
Product Description
1. Product lntroduction
S (standard)series pipe spray tank and cooling water tank
-Adopt MFGSP brand optimization configuration;
-5800 mm length and 304 stainless steel thickened vacuum tank;
- Newly optimized design of stainless steel pipe;
-The open sliding door structure is adopted for the specification above 250(including);
- Use plastic bucket filter and angle seat solenoid valve;
-The pipe drying device is added for the small-sized pipe;
- Adopt convex rubber seal.
G (high-end) series pipe spray tank and cooling water tank
- Adopt MFGSP brand optimization configuration;
-5800 mm length and 304 stainless steel thickened vacuum tank;
- Newly optimized design of stainless steel pipe;
-The open sliding door structure is adopted for the specification above 250(including);
-Use plastic bucket filter and angle seat solenoid valve;
-The pipe drying device is added for the small-sized pipe;
- Adopt convex rubber seal.
- Conform to CE standard design.
U (North American high-end) series pipe spray tank and cooling water tank
- Adopt MFGSP brand North American high-end confiquration;
-5800 mm length and 304 stainless steel thickened vacuum tank;
- Newly optimized design of stainless steel pipe;
- The open sliding door structure is adopted for the specification above 250 (including);
- Use plastic bucket filter and angle seat solenoid valve;
- The pipe drying device is added for the small-sized pipe;
-Adopt convex rubber seal.
-Equipped with independent circulating heat exchange device to realize the cooling water in the tank being clean and stable
- Conform to UL standard design;
-Developed and manufactured according to North American standard.
2.Product parameter
S(standard)series pipe spray tank and cooling water tank |
Model |
Spray pipe range (mm) |
Spray tank length (mm) |
Tank structure type |
Center height (mm) |
Overall dimension (mm) |
SC32S |
∅12~∅32 |
5800 |
Open type without cover |
1000 |
5800x300x1200 |
PL63S |
∅16~∅63 |
5800 |
Sealed tank type |
1000 |
5800x400x1360 |
PL160S |
∅20~∅160 |
5800 |
Sealed tank type |
1000 |
5800x500x1400 |
PL250S |
∅50~∅250 |
5800 |
Sealed tank type |
1000 |
5800x600x1500 |
PL315S |
∅75~∅315 |
5800 |
Sealed tank type |
1000 |
5800x700x1560 |
PL450S |
∅90~∅450 |
5800 |
Sealed tank type |
1100 |
5800x800x1600 |
PL630S |
∅160~∅630 |
5800 |
Sealed tank type |
1100 |
5800x900x1700 |
PL800S |
∅315~∅800 |
5800 |
Sealed tank type |
1200 |
5800x1900x2100 |
PL1000S |
∅400~∅1000 |
5800 |
Door pulling type |
1400 |
5800x2200x2300 |
PL1200S |
∅500~∅1200 |
5800 |
Door pulling type |
1600 |
5800x2400x2600 |
PL1600S |
∅710~∅1600 |
5800 |
Door pulling type |
1800 |
5800x2600x2800 |
G(high-end)series pipe spray tank and cooling water tank |
Model |
Spray pipe range (mm) |
Spray tank length (mm) |
Tank structure type |
Center height (mm) |
Overall dimension (mm) |
SC32G |
∅12~∅32 |
5800 |
Open type without cover |
1000 |
5800x300x1200 |
PL63G |
∅16~∅63 |
5800 |
Sealed tank type |
1000 |
5800x400x1360 |
PL160G |
∅20~∅160 |
5800 |
Sealed tank type |
1000 |
5800x500x1400 |
PL250G |
∅50~∅250 |
5800 |
Sealed tank type |
1000 |
5800x600x1500 |
PL315G |
∅75~∅315 |
5800 |
Sealed tank type |
1000 |
5800x700x1560 |
PL450G |
∅90~∅450 |
5800 |
Sealed tank type |
1100 |
5800x800x1600 |
PL630G |
∅160~∅630 |
5800 |
Sealed tank type |
1100 |
5800x900x1700 |
PL800G |
∅315~∅800 |
5800 |
Sealed tank type |
1200 |
5800x1900x2100 |
PL1000G |
∅400~∅1000 |
5800 |
Door pulling type |
1400 |
5800x2200x2300 |
PL1200G |
∅500~∅1200 |
5800 |
Door pulling type |
1600 |
5800x2400x2600 |
PL1600G |
∅710~∅1600 |
5800 |
Door pulling type |
1800 |
5800x2600x2800 |
U(North Ameican high-end)series pipe spray tank and cooling water tank |
Model |
Spray pipe range (mm) |
Spray tank length (mm) |
Tank structure type |
Center height (mm) |
Overall dimension (mm) |
SC32U |
∅12~∅32 |
5800 |
Open type without cover |
1000 |
5800x300x1200 |
PL63U |
∅16~∅63 |
5800 |
Sealed tank type |
1000 |
5800x400x1360 |
PL160U |
∅20~∅160 |
5800 |
Sealed tank type |
1000 |
5800x500x1400 |
PL250U |
∅50~∅250 |
5800 |
Sealed tank type |
1000 |
5800x600x1500 |
PL315U |
∅75~∅315 |
5800 |
Sealed tank type |
1000 |
5800x700x1560 |
PL450U |
∅90~∅450 |
5800 |
Sealed tank type |
1100 |
5800x800x1600 |
PL630U |
∅160~∅630 |
5800 |
Sealed tank type |
1100 |
5800x900x1700 |
PL800U |
∅315~∅800 |
5800 |
Sealed tank type |
1200 |
5800x1900x2100 |
PL1000U |
∅400~∅1000 |
5800 |
Door pulling type |
1400 |
5800x2200x2300 |
PL1200U |
∅500~∅1200 |
5800 |
Door pulling type |
1600 |
5800x2400x2600 |
PL1600U |
∅710~∅1600 |
5800 |
Door pulling type |
1800 |
5800x2600x2800 |
Debugging before shipping: Before shipping,all the lines will be strictly tested to ensure that customers use smoothly.
Installation at site: strict supervision for installation,commissioning and running.
Customers files establishment: detailed record on customers equipment information,and the replacement of spare parts are kept in profile for a long term save.
Regular visit system:after equipment installation and running,call to customers within one week,life-long follow-up service to the quality of products and services,to ensure that customers are worry-free.
Trouble shoot response time:establish professional sfter-sale service team,after breakdown happened,ensure engineers to provide solution within 24 hours,and solve the problem
Spare parts:Sufficiently supply,delivery in time
Professional skills&service